APPENDIX
B–63084EN/02
G. ALARM LIST
733
#7
ALD201
#6 #5 #4
EXP
#3 #2 #1 #0
When OVL equal 1 in diagnostic data No.200 (servo alarm No. 400 is
being generated):
#7 (ALD) 0 : Motor overheating
1 : Amplifier overheating
When FBAL equal 1 in diagnostic data No.200 (servo alarm No. 416 is
being generated):
ALD EXP Alarm details
1 0 Built–in pulse coder disconnection (hardware)
1 1 Separately installed pulse coder disconnection
(hardware)
0 0 Pulse coder is not connected due to software.
#7
204
#6
OFS
#5
MCC
#4
LDA
#3
PMS
#2 #1 #0
#6 (OFS) : A current conversion error has occured in the digital servo.
#5 (MCC) : A magnetic contactor contact in the servo amplifier has welded.
#4 (LDA) : The LED indicates that serial pulse coder C is defective.
#3 (PMS) : A feedback pulse error has occured because the feedback cable is
defective.
6) Over travel alamrs
Number Message Contents
500 OVER TRAVEL : +n Exceeded the n–th axis + side stored stroke limit I.
(Parameter No.1320 or 1326 Notes)
501 OVER TRAVEL : –n Exceeded the n–th axis – side stored stroke limit I.
(Parameter No.1321 or 1327 Notes)
502 OVER TRAVEL : +n Exceeded the n–th axis + side stored stroke limit II.
(Parameter No.1322 )
503 OVER TRAVEL : –n Exceeded the n–th axis – side stored stroke limit II.
(Parameter No.1323)
504 OVER TRAVEL : +n Exceeded the n–th axis + side stored stroke limit III.
(Parameter No.1324 )
505 OVER TRAVEL : –n Exceeded the n–th axis – side stored stroke limit III.
(Parameter No.1325 )
506 OVER TRAVEL : +n Exceeded the n–th axis + side hardware OT.
507 OVER TRAVEL : –n Exceeded the n–th axis – side hardware OT.
508 INTERFERENCE : +n When n–axis is moving in the positive direction, it interferes with the or-
der tool post (only with two–path control)
509 INTERFERENCE : –n When n–axis is moving in the negative direction, it interferes with the or-
der tool post (only with two–path control)
510 OVER TRAVEL : +n A stroke limit check, made before starting movement, found that the end
point of a block falls within the plus (+) side inhibited area along the n–
axis defined by a stroke limit. Correct the program.
511 OVER TRAVEL : –n A stroke limit check, made before starting movement, found that the end
point of a block falls within the minus (–) side inhibited area along the
N–axis defined by a stroke limit. Correct the program.