Series 30i-MODEL A, Rapid traverse override 0.1% Additional Manual Page 6

Additional Manual
Design Ed.
Approve
Design
page
Title
Draw.
No.
4/7
Description
FANUC Series 30i-MODEL A
Rapid traverse override 0.1%
A-79367E
Jan. 13, 2004
Date
Date
- 0.1% step rapid traverse override selection signal
0.1% step rapid traverse override selection signal FHROV determines
whether 1% step rapid traverse override is used or 0.1% step rapid traverse
override is used.
When signal HROV is 1 and signal FHROV is 0, 1% step rapid travers
override is applied.
When signal HROV is 1 and signal FHROV is 1, 1% step rapid travers
override is ignored, 0.1% step rapid traverse override signals *FHRO0 to
*FHRO9 being used to override the rapid traverse rate.
- PMC axis control
These 1% step rapid traverse override signals and 0.1% step rapid traverse
override signals are also effective to the rapid traverse rate for the PMC axis.
When rapid traverse override is applied to the PMC axis (using signals
ROV1E and ROV2E) with the setting of the OVE bit (bit 2 of parameter No.
8001) independently of the CNC, the 1% step rapid traverse override signals
and the 0.1% step rapid traverse override signals are ineffective.
Signal
Rapid traverse override signal ROV1,ROV2<Gn014#0,#1>
[Classification] Input signal
[Function] These signals override the rapid traverse rate
[Operation] These code signals correspond to the rates as follows (Table 7.1.7 (a)):
Table 7.1.7 (a) Signals ROV1 to ROV2 and override value
Rapid traverse override
ROV2 ROV1
Override value
0
0
1
1
0
1
0
1
100%
50%
25%
F0
F0 : Set in parameter No. 1421
1% step rapid traverse override selection signal HROV<Gn096#7>
[Classification] Input signal
[Function] Selects the rapid traverse override signals or the 1% step rapid traverse
override signals.
[Operation] When this signal is set to 1, the values of *HROV0 to *HROV6 are enabled.
(Rapid traverse override by signals ROV1 and ROV2 is disabled.)
When this signal is set to 0, Rapid traverse override by signals ROV1 and
ROV2 is enabled. (the values of *HROV0 to *HROV6 are disabled.)

Contents Summary of Series 30i-MODEL A, Rapid traverse override 0.1% Additional Manual

  • Page 1TECHNICAL REPORT NO. TMN 04/020E Date :Mar .30, 2004 General Manager of Software Laboratory FANUC Series 30i-A Newly additional functions 1. Communicate this report to: Your information only GE Fanuc-N, GE Fanuc-E FANUC Robotics MILACRON Machine tool builder Sales agency End user 2. Summary for Sale
  • Page 2FANUC Series30i –A newly additional functions Drawing number Functions 1 A-79227E External Data Input 2 A-79226E One Touch Macro call 3 A-79196E Temporary absolute coordinate setting 4 A-79354E System alarm 5 A-79349E Touch Panel Control 6 A-79253E Distance coded linear scale interface 7 A-79364E Li
  • Page 3FANUC Series 30i-MODEL A Rapid traverse override 0.1% Specifications FANUC Series 30i-MODEL A Title Rapid traverse override 0.1% Draw. No. A-79367E Ed. Date Design Description page 1/7 Date Jan. 13, 2004 Design Approve
  • Page 4"7.1.7.1 Rapid traverse override" of the B-63943EN-1 CONNECTION MANUAL (FUNCTION) is replaced as following. FANUC Series 30i-MODEL A Title Rapid traverse override 0.1% Draw. No. A-79367E Ed. Date Design Description page 2/7 Date Jan. 13, 2004 Design Approve
  • Page 51.1.1.1 Rapid traverse override Overview An override of four steps (F0, 25%, 50%, and 100%) can be applied to the rapid traverse rate. F0 is set by a parameter (No. 1421). Also, 1% rapid traverse override select signal and 0.1% rapid traverse override select signal allow rapid traverse override ever
  • Page 6- 0.1% step rapid traverse override selection signal 0.1% step rapid traverse override selection signal FHROV determines whether 1% step rapid traverse override is used or 0.1% step rapid traverse override is used. When signal HROV is 1 and signal FHROV is 0, 1% step rapid travers override is applie
  • Page 71% step rapid traverse override signals *HROV0 to *HROV6 [Classification] Input signal [Function] Applies override to the rapid traverse rate in the range of 0% to 100% in steps of 1%. [Operation] These seven signals give a binary code indicating an override applied to the rapid trave
  • Page 8Parameter 1421 F0 rate of rapid traverse override for each axis [Input type] Parameter input [Data type] Real axis [Unit of data] mm/min, inch/min, degree/min (machine unit) [Minimum unit of data] Depend on the increment system of the applied axis [Valid data range] Refer to the standard parameter s
  • Page 9#7 #6 #5 #4 #3 #2 #1 #0 8001 OVE [Input type] Parameter input [Data type] Bit path #2 OVE Signals related to dry run and override used in PMC axis control 0: Same signals as those used for the CNC 1: Signals specific to the PMC The signals used depend on the settings of these parameter bits as indic