Series 30i-MODEL A, Rapid traverse override 0.1% Additional Manual Page 8

Additional Manual
Design Ed.
Approve
Design
page
Title
Draw.
No.
6/7
Description
FANUC Series 30i-MODEL A
Rapid traverse override 0.1%
A-79367E
Jan. 13, 2004
Date
Date
Parameter
1421 F0 rate of rapid traverse override for each axis
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Set the F0 rate of the rapid traverse override for each axis.
#7 #6 #5 #4 #3 #2 #1 #0
3002 IOV
[Input type] Parameter input
[Data type] Bit path
# 4 IOV Override-related signal logic is:
0: Used without modification
(A signal of negative logic is used as a negative logic signal, and a
signal of positive logic is used as a positive logic signal.)
1: Inverted
(A signal of negative logic is used as a positive logic signal, and a
signal of positive logic is used as a negative logic signal.)
The signals indicated below are affected.
Signal of negative logic:
Feedrate override signals *FV0 to *FV7<Gn012>
Second feedrate override signals*AFV0 to *AFV7<Gn013>
Feedrate override signals (for PMCaxis control)
*EFOV0g to *EFOV7g<G0151/G0163/G0175/G0187>
Software operator’s panel signals *FV0O to *FV7O<Fn078>
Signals of positive logic:
Rapid traverse override signals ROV1,ROV2<Gn014#0,#1>
Software operator’s panel signals ROV1O,ROV2O<Fn076#4,#5>
Rapid traverse override signals (for PMCaxis control)
EROV1g,EROV2g<G0150#0,#1, G0162#0,#1, G0174#0,#1,
G0186#0,#1>
The signals indicated below are not affected.
1% step rapid traverse override selection signal HROV<Gn096#7>
1% step rapid traverse override signals *HROV0 to *HROV6
<Gn096#0 to #6>
0.1% step rapid traverse override selection signal FHROV<Gn353#7>
0.1% step rapid traverse override signals *FHRO0 to *FHRO9
<Gn352#0 to #7,Gn353#0 to #1>

Contents Summary of Series 30i-MODEL A, Rapid traverse override 0.1% Additional Manual

  • Page 1TECHNICAL REPORT NO. TMN 04/020E Date :Mar .30, 2004 General Manager of Software Laboratory FANUC Series 30i-A Newly additional functions 1. Communicate this report to: Your information only GE Fanuc-N, GE Fanuc-E FANUC Robotics MILACRON Machine tool builder Sales agency End user 2. Summary for Sale
  • Page 2FANUC Series30i –A newly additional functions Drawing number Functions 1 A-79227E External Data Input 2 A-79226E One Touch Macro call 3 A-79196E Temporary absolute coordinate setting 4 A-79354E System alarm 5 A-79349E Touch Panel Control 6 A-79253E Distance coded linear scale interface 7 A-79364E Li
  • Page 3FANUC Series 30i-MODEL A Rapid traverse override 0.1% Specifications FANUC Series 30i-MODEL A Title Rapid traverse override 0.1% Draw. No. A-79367E Ed. Date Design Description page 1/7 Date Jan. 13, 2004 Design Approve
  • Page 4"7.1.7.1 Rapid traverse override" of the B-63943EN-1 CONNECTION MANUAL (FUNCTION) is replaced as following. FANUC Series 30i-MODEL A Title Rapid traverse override 0.1% Draw. No. A-79367E Ed. Date Design Description page 2/7 Date Jan. 13, 2004 Design Approve
  • Page 51.1.1.1 Rapid traverse override Overview An override of four steps (F0, 25%, 50%, and 100%) can be applied to the rapid traverse rate. F0 is set by a parameter (No. 1421). Also, 1% rapid traverse override select signal and 0.1% rapid traverse override select signal allow rapid traverse override ever
  • Page 6- 0.1% step rapid traverse override selection signal 0.1% step rapid traverse override selection signal FHROV determines whether 1% step rapid traverse override is used or 0.1% step rapid traverse override is used. When signal HROV is 1 and signal FHROV is 0, 1% step rapid travers override is applie
  • Page 71% step rapid traverse override signals *HROV0 to *HROV6 [Classification] Input signal [Function] Applies override to the rapid traverse rate in the range of 0% to 100% in steps of 1%. [Operation] These seven signals give a binary code indicating an override applied to the rapid trave
  • Page 8Parameter 1421 F0 rate of rapid traverse override for each axis [Input type] Parameter input [Data type] Real axis [Unit of data] mm/min, inch/min, degree/min (machine unit) [Minimum unit of data] Depend on the increment system of the applied axis [Valid data range] Refer to the standard parameter s
  • Page 9#7 #6 #5 #4 #3 #2 #1 #0 8001 OVE [Input type] Parameter input [Data type] Bit path #2 OVE Signals related to dry run and override used in PMC axis control 0: Same signals as those used for the CNC 1: Signals specific to the PMC The signals used depend on the settings of these parameter bits as indic