FANUC Series16i/18i/21i-A/B
Setting method of
the Ethernet default address
A-78770EN
2002.05.09
Kageyama
4. Notes
(1) In case that the default address is set to embedded Ethernet, PCMCIA Ethernet is not used
and embedded Ethernet is selected.
(2) In case that the default address is set to PCMCIA Ethernet, embedded Ethernet is not used
and PCMCIA Ethernet is selected.
(3) In case that Ethernet board, embedded Ethernet and PCMCIA Ethernet are invalid, when the
push switch is held down for five seconds, the 7-segment LED does not blink. Therefore, the
default address can not set.
(4) This operation is enable to connect CNC with a personal computer by one-to-one. To change
the final Ethernet address is set by a personal computer or CNC.
(5) When the Ethernet default address is set, automatic operation must be stopped.
(6) When the CNC is already connected with some devices via network, do not perform this
operation, because there is a possibility that the IP address conflicts with another device in the
network.
(7) Embedded Ethernet and PCMCIA Ethernet is valid with F16i/18i/21i model B.