Contents Summary of FS 16i/18i/21i-A/B, Setting Method of the Ethernet default address Supplement to Manual
Page 1FANUC Series 16i/18i/21i - A/B Setting method of the Ethernet default address Specifications FANUC Series16i/18i/21i-A/B Title Setting method of the Ethernet default address Draw No. A-78770EN Edit Date Design Description Sheet 0 /5 Date 2002.05.09 Desig. Kageyama Apprv.
Page 2FANUC Series 16i/18i/21i - A/B Setting method of the Ethernet default address Specifications Contents 1. Outline …2 2. Setting method …2 3. Default address …4 4. Notes …5 FANUC Series16i/18i/21i-A/B Title Setting method of the Ethernet default address Draw No. A-78770EN Edit Date Design Description
Page 31. Outline In case of stand-alone type FANUC series 16i/18i/21i, the Ethernet default address can be set by 7-segment LED and push switch. This default address is enable to connect CNC with a personal computer by one-to-one. The final Ethernet address connected to the network need to be set by a per
Page 4(17) In case that the Ethernet default address is set to Ethernet board, when “1” is displayed on the 7-segment LED, press the push switch. When Ethernet board is invalid, “1” is not displayed on the 7-segment LED. (18) In case that the Ethernet default address is set to embedded Ethernet, when “2”
Page 53. Default address The Ethernet default address is as follows. CNC IP address : 192.168.1.1 SUBNET MASK : 255.255.255.0 TCP PORT number : 8193 UDP PORT number :0 TIME INTERVAL :0 FANUC Series16i/18i/21i-A/B Title Setting method of the Ethernet default address Draw No. A-78770EN Edit Date Design Desc
Page 64. Notes (1) In case that the default address is set to embedded Ethernet, PCMCIA Ethernet is not used and embedded Ethernet is selected. (2) In case that the default address is set to PCMCIA Ethernet, embedded Ethernet is not used and PCMCIA Ethernet is selected. (3) In case that Ethernet board, em