Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
12
12
Date
Design
Descri
tion
Date
FANUC Series16i/18i/21i–MA/TA
Automatic operation and temporary
storage of external program
-78620
09.Oct.’01 T.Endo H.Kochiya
Data No.
Data
12017
M code for registering part program into temporary storage memory
Data type Word
Valid data
range
1-999
This parameter sets the M code which instructs to register part program
into temporary storage memory. If the parameter is set to 0, M298 is
used.
Data No.
Data
12018
M code for program registration completion waiting
Data type Word
Valid data
range
1-999
This parameter sets the M code which instructs to wait program
registration completion. If the parameter is set to 0, M297 is used.
Data No.
Data
12019
M code for deleting program on temporary storage memory
Data type Word
Valid data
range
1-999
This parameter sets the M code which instructs to delete program on
temporary storage memory. If the parameter is set to 0, M296 is used.