EDIT DATE DESIG.
TITLE
DESCRIPTION
A-80035E
2
/
8
1. Overview
Relay
Module A has 10 relays and is used when driving the load of the exceeding the rated current
of the Connector Panel I/O Module
’
s DO. This module is connected to the Terminal module A
“
A03B-0815-C021
”
which the Connector Panel I/O Module is mounted on with a flat cable. And
connect one more this module when all of the Connector Panel I/O Module
’
s 16 points of DO are
used.
2. Total Connection
Note) The first Relay Module A drives 10 relays by 10 points of DO. And the second Relay module A
drives 10 relays by 6 points of DO. (In 2 relays, 1 relay is driven by 1 point of DO. In other 8
relays, 2 relays are driven by 1 point of DO.)
Note) Don
’
t connect the DO used in the Relay module A to Terminal module A side.
Extension Module 3 Terminal module A
Extension Module 1 Terminal module A
Machine side
DI/DO
+24V
Power source
Basic Module Terminal module A
CA52
CA53
CA52
CB150
JD1B
CA52
CA53
CA52
CA53
CB150
X150
XT150A/B
XP1 XP2
Relay Module A Relay module A
XP1
XP1 XP2
XP1 XP2
XP1 XP2
Relay contact
output
XT1 XT1
XT1
XT1
XT1
I/O LINK
JD1A
CB150
CB150
CB150
CB150
CB150
CB150
X150
XT150A/B
X150
XT150A/B
X150
XT150A/B
XP1
XT1
XP1
XT1
XP1
XT1
Extension Module 2 Terminal module A
Relay Module A Relay module A
Relay Module A Relay module A
Relay Module A Relay module A
CNC