4/28
SHEET
DESCRIPTION
DESIGN
DATE
EDIT
01
FANUC LTD.
DRAW.NO.
Matsukura
Newl
re
istered
TITLE:
FANUC CIMPLICITY i CELL
OPERATOR’S MANUAL
06.01.25
B-75074EN/05-1
I.1 Installation of CIMPLICITY HMI 6.1 Service Pack 4
It is necessary to install CIMPLICITY HMI 6.1 Service Pack 4 (SP4) and
the Hotfix 072105_22989_6104 to use CIMPLICITY HMI 6.1 with
Windows XP SP2. Please install each file after installing CIMPLICITY HMI
6.1.
The following two files are required;
(1) CIMPLICITY HMI 6.1 SP4 (file name is HMI6.1SP4.exe)
(2) HotFix 072105_22989_6104 (file name is 072105_22989_6104.zip)
These two files are compressed files. Please install these files after extracing.
Required hard disk space to install these files are as follows. Install these
after confirming the hard disk space.
Before
extract
After
extract
Installation
CIMPLICITY HMI 6.1 SP4 32.4MB 33.9MB 25MB
Hotfix 072105_22989_6104 1.5MB 2.0MB 6MB
Total 105MB
Installation procedure
Note
To install these files, it is necessary to use an Administrators
group's (manager of the computer) user name.
Install each file according to the following procedures.
1. Confirm that the CIMPLICITY project is not operated and CIMPLICITY
screen is not displayed.
2. Copy (1)HMI6.1SP4.exe and (2)072105_22989_6104.zip files to an
arbitrary folder in your PC.
3. Run (1)HMI6.1SP4.exe and extract (2)072105_22989_6104.zip. The
following folders will be created where compressed files are exist.
(1) HMI6.1SP4
(2) 072105_22989_6104
4. Execute setup.bat in the created folder HMI6.1SP4.
The installer will be activated and install it according to the instruction of
the screen.
5. The installer of the iHistorian(data base special to preserve the point
data) client software is automatically called during the installation.
When you doesn't use the iHistorian, and when the installation of the
client software of iHistorian is unnecessary, this installation can be
canceled. The iHistorian is not used in the i CELL.
The procedure for installing or canceling installation of the iHistorian