13 / 14
Date
Signature
Descri
tion
FANUC Series 30i-MODEL A
Power Mate CNC Manager
A-79260E
01 Newly Design
Title
Draw
No.
page
2004.01.07
8760
Program number of data I/O
(
Power Mate CNC Manager
)
[Input type] Setting input
[Data type] 2-word path
[Valid data range] 0
−
99999999
Set the program number that saves and restores the slave
data(parameter) in Power Mate CNC Manager.
For a I/O Link
β
in channel m and group n, the following program
numbers are used:
Program number = setting + (m-1) ×100+n×10
If the parameter setting is zero, the parameter of the slvave that is
connected to channel 1 and group0 is zero cannot be input/output
from/to the CNC srtage memory because the program number is zero. It
can be input/output from/to the memory card even if the program
nnumber is zero.
(Set the value not to the program number over 99999999)
Warning
When the alarm occures in the Power Mate CNC Manager, the warning message displays
Message Contents
DATA ERROR An attempt was made to punch a program not found in the program
area using “PUNCH” (NC → β).
WRITE PROTECT
An attempt was made to execute “READ” (β → NC) on the progra
m area when the memory protection key (KEY) was off.
EDIT REJECTED
An attempt was made to execute “READ” (β → NC) when the prog
ram area already contained a program with the
same name as that to be created by executing ”READ” ( β → NC)
An attempt was made to execute “READ” ( β → NC) when the sa
me program number as that of the program to be
created by executing “READ” ( β → NC) was selected.
An attempt was made to execute “READ” ( β → NC) when the pa
rameter TVC (No.0 bit0)is set to’1’ ( The parameterNo.0 to 19 is ou
tput, but later the No.20 are not output )
An attempt was made to execute “PUNCH” (NC →β ) when the memory
card did not contain a program to perform “PUNCH” (NC →
β ).
An attempt was made to execute “READ” ( β → NC) when the m
emory card was protected.
NO MORE SPACE
An attempt was made to execute “READ” ( β → NC) when the pr
ogram area did not have enough free space.
FORMAT ERROR
Data other than digits, signs, CAN, and INPUT was entered as a
parameter setting.
TOO MANY DIGITS Data of 9 or more digits was entered for a bit-type parameter.
DATA IS OUT OF RANGE The setting exceeds the valid data range.