• Connecting an I/O Link
When the β amplifier with I/O Link is used as a slave of an I/O Link, the CNC assigns I/O
addresses. The salve data is input and output in units of 16 bytes. Therefore, 128 input/output
points are necessary. Up to eight slaves can be connected.
The module name is OC021 (16–byte input) or OC020 (16–byte output).
BASE is always 0, and SLOT is always 1.
・ Ignore the Power Mate
CNC Manager function
After the data necessary for each slave connected is set and checked, the communication of
the Power Mate CNC Manager can be stopped to send a command from the CNC ladder to the
slave.
When the PMN (bit 3 of parameter 960) is set to 1, all communication between CNC and
the slave via the I/O Link is open to the ladder. And if this bit of parameter is set to 1, Power
Mate CNC Manager is not available.
• Data protection key
When the data protection key of the CNC is turned on, parameters can not be input to CNC
memory.
NOTE
This function is optional.