Contents Summary of FS 16i/18i/21i-TB/MB, FS 18i-MB5, FS 16i/18i-TA/MA, Expansion of Custom Macro Interface Signal Additional Manual
Page 1FANUC Series 16i / 18i / 21i – TB / MB FANUC Series 18i – MB5 FANUC Series 16i / 18i – TA / MA Expansion of Custom Macro Interface Signal Specifications Name FS16i/18i/21i-TB/MB/TA/MA Expansion of Custom Macro Interface Signal No. A-61002E Ed. Date Contents Page 1/10 Draw up 2002.09.12
Page 31.1 General This function expands the custom macro interface signals. Name FS16i/18i/21i-TB/MB/TA/MA Expansion of Custom Macro Interface Signal No. A-61002E Ed. Date Contents Page 3/10 Draw up 2002.09.12
Page 41.2 Detail Interface signals for custom macro can be expanded by setting the parameter MIF(No.6001#0) "1". (Note) In case of i series model-A, PMC-SB6 is needed. Input signals : UI000 - UI031 #1000 - #1031, #1032 UI100 - UI131 #1033 UI200 - UI231 #1034 UI300 - UI331 #1035 Output signals : UO000 - UO
Page 5Interface Signals / Input Signal The statuses of interface signals are available by reading the system variables. System Parameter MIF(No.6001#0) = "0" Parameter MIF(No.6001#0) = "1" Variables Q'ty Interface Input Signals Q'ty Interface Input Signals #1000 1 UI000 1 UI000 #1001 1 UI001 1 UI001 #1002
Page 6Interface Signals / Output Signal Interface signals can be transmitted by assigning values to the system variables. System Parameter MIF(No.6001#0) = "0" Parameter MIF(No.6001#0) = "1" Variables Q'ty Interface Output Signals Q'ty Interface Output Signals #1100 1 UO000 1 UO000 #1101 1 UO001 1 UO001 #
Page 71.3 Parameter #7 #6 #5 #4 #3 #2 #1 #0 6001 MIF [Data type] Bit MIF Expansion of Custom Macro Interface Signal is 1: not available. 0: available. Name FS16i/18i/21i-TB/MB/TA/MA Expansion of Custom Macro Interface Signal No. A-61002E Ed. Date Contents Page 7/10 Draw up 2002.09.12