EDT DATE
A
-77497-EN
10 / 15
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
FANUC Series 16 i
Spindle setting, tuning
and monitor screen
01 1998.12.18
newly registered
LOAD METER ---- The load meter displays spindle load in a unit of 10%, and
maximum displayed value of the load meter varies depending on
parameter No.4127. When the spindle switching function is applied
and sub spindle is selected, it varies depending on parameter
No.4274.
Max. 10 control input signals which are ON are displayed from the following signals.
Max. 10 control output signals which are ON are displayed from the following signals.
Signal M eaning Signal M eaning
TLM L
Torque limit com m and (low )
SPSL
Spindle selection signal
TLM H
Torque limit com m and (high)
MCFN
Power line sw itching
CTH1
Gear signal 1
SOCN
Soft start/stop cancel
CTH2
Gear signal 2
INTG
Speed integral control signal
SRV
Spindle re ve rse ro tation
RSL
Output sw itching request
SFR
Spindle forw ard ro tation
RCH
Power line state confirm
ORCM
Spindle orientation
INDX
Orientation stop pos. change
MRDY
M achine re ad y
ROTA
Rotation direction of ORCM
ARST
Alarm re se t signal
NRRO
Short-cut of ORCM
*ESP
Em ergency stop
DEFM
Referencial m ode com m and
Signals M eaning Signal
Meaning
ALM
Alarm signal
TLM S
Torque limitation
SST
Speed zero signal
ORAR
Orientation end signal
SDT
Speed detecting signal
CHP
Power line sw itched signal
SAR
Speed arrival signal
CFIN
Spindle sw itch com plete signal
LDT1
Load detecting signal 1
RCHP
Output sw itch signal
LDT2
Load detecting signal 2
RCFN
Output sw itch com plete signal