EDT DATE
A
-77497-EN
11 / 15
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
FANUC Series 16 i
Spindle setting, tuning
and monitor screen
01 1998.12.18
newly registered
3. Parameters of screen display
3-1 Setting of screen display
SPS Spindle setting screen is 1 : displayed.
0 : not displayed.
SVP Synchronization errors displayed on the spindle tuning screen
1 : Peak-hold values are displayed.
0 : instantaneous values are displayed.
(SVP is a parameter common to rigid tapping and
synchronization control.)
ESP 1 : Displayed spindle is only the first spindle.
0 : The number of displayed spindles depends on the parameter
No.3701#5,#4.
3-2 Setting of the number of displayed spindles
SS2 In serial spindle control, the second spindle is 1 : used.
0 : not used.
SS3 In serial spindle control, the third spindle is 1 : used.
0 : not used.
SS2 and SS3 described above are originally parameters of serial spindle connection, but the
number of displayed spindles depends on these parameters as showed below.
PRM No.76543210
3111 ESP SVP SPS
PRM No.76543210
3701 SS3 SS2
Setting of SS2 0 1 0
Setting of SS3 0 0 1
The num ber of displayed spindles123