A-79253E
Title
Draw
No.
Ed. Date Design Description
Date Jan.06.’04 Design. Apprv.
11/18
Page
FANUC Series 30i-MODEL A
Distance coded linear scale interface
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1802 DC2x DC4x
[Input type] Parameter input
[Data type] Bit axis
# 1 DC4x When the reference point is established by the distance coded linear scale,
0 : The axis moves until three reference marks are detected.
1 : The axis moves until four reference marks are detected.
# 2 DC2x When the reference point is established by the distance coded linear scale,
0 : The axis moving depends on the setting of the parameterDC4.
1 : The axis moves until two reference marks are detected.
Note
1. When this parameter is set to 1, set the direction of scale
zero in the parameter (No.1817#4(SCP)) correctly.
2. Even if DC2 is "1", the rotary
axis(parameter1815#3(DCR)=1) follows DC4.
#7 #6 #5 #4 #3 #2 #1 #0
1815 DCRx DCLx OPTx
[Input type] Parameter input
[Data type] Bit axis
Note
When this parameter is set, the power must be turned off
before operation is continued.
# 1 OPTx Position detector
0 : A separate pulse coder is not used.
1 : A separate pulse coder is used.
Note
Set “1” when a distance coded linear scale is used.
# 2 DCLx As a separate position detector, the linear scale with a distance coded linear
scale
0 : Not used.
1 : Used.