A-79253E
Title
Draw
No.
Ed. Date Design Description
Date Jan.06.’04 Design. Apprv.
12/18
Page
FANUC Series 30i-MODEL A
Distance coded linear scale interface
Note
Set “1” when a distance coded linear scale is used.
# 3 DCRx As the scale with absolute addressing reference marks:
0 : The linear scale is used.
1 : The rotary encoder is used.
Note
Set “1” of the parameter DCLx (No.1815#2) when the rotary
encoder with absolute addressing reference marks is used.
#7 #6 #5 #4 #3 #2 #1 #0
1818 RF2x RFSx
[Input type] Parameter input
[Data type]
Bit axis
# 0 RFSx When the conditions are as follows, the axis moves to intermediate position
and the reference position is not established, and:
0 : the axis moves to the reference point.
1 : sequence complete without moving to the reference point.
(Conditions)
- Reference position is not established (ZRFn=0).
-
Automatic reference position return (G28) is commanded.
# 1 RF2x When the conditions are as follows,
0 : the axis moves to the reference point.
1 : sequence complete without moving to intermediate position or reference
position.
(Conditions)
- Reference position is established (ZRFn=1).
-
Automatic reference position return (G28) is commanded.