A-79253E
Title
Draw
No.
Ed. Date Design Description
Date Jan.06.’04 Design. Apprv.
14/18
Page
FANUC Series 30i-MODEL A
Distance coded linear scale interface
1883 Distance between scale zero and reference position (1)
Note
When this parameter is set, the power must be turned off
before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] -999999999 to 999999999
Set the interval of reference mark 2 of distance coded linear scale.
1884 Distance between scale zero and reference position (2)
Note
When this parameter is set, the power must be turned off
before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] -999 to 999
When the distance between scale zero and reference position is over the
setting range of parameter 1883, please set this parameter.
Set the distance between scale zero and reference position by parameter
No.1883, 1884. The actual distance is determined by following formula :
ctual distance =
Parameter 1884 * 1,000,000,000 + Parameter