QuickTurn™
GFKE-0201B-EN - 29 - GE Fanuc Automation S.A.
X10.0 Override 1
Rotary Switch
X10.1 Override 2
Rotary Switch
X10.2 Override 3
Rotary Switch
X10.3 Override 4
Rotary Switch
X10 bit3 bit2 bit1 bit0
0 Æ 0 0 0 0 Jog/Cycle=0% Rapid=10% (Parameter 1421)
1 Æ 0 0 0 1 Jog/Cycle=5% Rapid=10% (Parameter 1421)
2 Æ 0 0 1 0 Jog/Cycle=10% Rapid=10% (Parameter 1421)
3 Æ 0 0 1 1 Jog/Cycle=20% Rapid=25%
4 Æ 0 1 0 0 Jog/Cycle=40% Rapid=25%
5 Æ 0 1 0 1 Jog/Cycle=60% Rapid=50%
6 Æ 0 1 1 0 Jog/Cycle=80% Rapid=50%
7 Æ 0 1 1 1 Jog/Cycle=100% Rapid=100%
8 Æ 1 0 0 0 Jog/Cycle=120% Rapid=100%
9 Æ 1 0 0 1 Jog/Cycle=140% Rapid=100%
X10.4 Push Button Coolant On/Off
0: No Effect
1: Coolant On/OFF (Pulse)
X10.5 Reference Mode Selector Switch
Rotary Switch
0: No Effect
1: Reference Mode ON
X10.6 MPG Increment selector Bit 1
Rotary Switch
X10.7 MPG Increment selector Bit 2
Rotary Switch
X10 bit6 bit7
0 0 Stop MPG (Manual Pulse Coder)
0 1 Increment 0.001
1 0 Increment 0.01
1 1 Increment 0.1
X11.7 Push Button Decrease Operation by 1 0: No Effect
1: Decrease Op. by 1 (Pulse)