A-221443/01E
(*1) When the output switch function is used, the CNC soft option
and switching magnetic contactor unit associated with the
output switch function (Y-∆ switch) are required.
See FANUC SERVO AMPLIFIER αi series DESCRIPTIONS
(B-65282EN) for details of the output switch control.
(*2) The rated output is guaranteed at the rated voltage.
(Amplifier input: 400/480VAC +10% -15%, 50/60 Hz ±1Hz)
If the input voltage fluctuates, it is possible that the rated output
cannot be obtained even when such fluctuations are within the
allowable fluctuation range.
(*3) The output for low-speed winding models is 15 min rated.
(*4) S3 15% for low-speed winding models.
(*5) The cycle time is 10 minutes, S3 60%: ON 6 minutes, OFF 4
minutes and S3 15%: ON 1.5 minutes, OFF 8.5 minutes.
(*6) The rated current is not a guaranteed value but a guideline for
the maximum current at each rated output.
(*7) IC code conforms to IEC 34-6.
(*8) IM code conforms to IEC 34-7.
(*9) This is not a guaranteed value but a guideline for the maximum
motor output at a rated supply voltage.
(*10) Type conforms to IEC 34-11.
(*11) Use the motor output shaft below the allowable radial loads. If an
excessive load is applied, consider the use of a support bearing on
the machine side to maintain the long-term reliabilty of the motor.
(If an excessive load is applied, it is possible that an abnormal sound
may occur.)
(*12) These values are to be used only as guidance for selecting a
power supply module and are not guaranteed.
(*13) Degree of protection:IP40.