A-221443/01E
4.Spindle parameter table [SPINDLE HRV Control] (2005.06.23)
MTB: GENERAL
Spindle Motor: A06B-1549-B113
α
iIP 15/8000HV αiMZ sensor 256 teeth
Spindle Amplifier: A06B-6121-H015#H550
α
iSP 15HV (TYPE A)
For FS16i, FS15i
A06B-6121-H015#H570
α
iSP 15HV (TYPE A)
For FS30i
Low speed range High speed range
Parameter No. 5 / 9 kW Parameter No. 7.5 / 9 KW
FS15i FS16i FS30i
500 / 1500
min
-1
FS15i FS16i FS30i
750 / 8000
min
-1
3001 4001 4001 00000001
3002 4002 4002 00000000
3003 4003 4003 00000000
3004 4004 4004 00000000
3006 4006 4006 00000000
3007 4007 4007 00000000
3008 4008 4008 00000000
3009 4009 4009 00000000
3010 4010 4010 00000001
3011 4011 4011 00011010
3012 4012 4012 10000010
3013 4013 4013 00001100
3019 4019 4019 00000100
3020 4020 4020 8000
3023 4023 4023 94
3156 4156 4156 0 3039 4039 4039 0
3166 4166 4166 80 3080 4080 4080 95
3138 4138 4138 530 3100 4100 4100 760
3139 4139 4139 75 3101 4101 4101 90
3140 4140 4140 726 3102 4102 4102 1460
3141 4141 4141 75 3103 4103 4103 60
3142 4142 4142 10000 3104 4104 4104 5000
3105 4105 4105 0
3143 4143 4143 28000 3106 4106 4106 12000
3107 4107 4107 0
3144 4144 4144 0 3108 4108 4108 0
3145 4145 4145 25 3109 4109 4109 25
3146 4146 4146 1934 3110 4110 4110 1384
3147 4147 4147 465 3111 4111 4111 330
3148 4148 4148 200 3112 4112 4112 200
3149 4149 4149 330 3113 4113 4113 260
3150 4150 4150 0 3114 4114 4114 0
3151 4151 4151 100 3115 4115 4115 100
3152 4152 4152 5167 3116 4116 4116 4600
3153 4153 4153 90 3117 4117 4117 90
3154 4154 4154 100 3118 4118 4118 100
3165 4165 4165 29 3119 4119 4119 37
3120 4120 4120 0
3155 4155 4155 0 3124 4124 4124 0
3093 4093 4093 216 3127 4127 4127 144
3158 4158 4158 0 3128 4128 4128 103
3159 4159 4159 0 3129 4129 4129 0
3161 4161 4161 25700 3130 4130 4130 25700
3134 4134 4134 130
3169 4169 4169 0
Maximum power at acceleration (for selecting PSM): 13.5kW
[Parameter setting procedure]
(1) Load parameters
automatically with the model
code 400.
Note) If you don't want to
initialize adjusted
parameters, you should not
load parameters
automatically.
(2) Change parameters
manually according to the
table.
(3) Set sensor parameters
according to the sensor
system.
(4) Power off/on to activate the
SPINDLE HRV Control
parameters surely.