2.HOW TO USE SERVO MOTORS SPECIFICATIONS FOR THE βiS SERIES B-65302EN/01
- 20 -
2.2.3.4 Connectors on the cable side (for power and brake : models
β
ββ
β0.2is and β
ββ
β0.3is)
Dedicated connectors which are TÜV approved are available as the
connector for power for the β0.2is and β0.3is.
The following subsection describes the specifications as a connector
kit. These connectors are dripproof when engaged.
To connect the cable, a dedicated crimping tool must be used.
Consider crimping and cable clamp. Also note that there are
restrictions.
For power and brake
Housing specification
(Tyco Electronics AMP)
3-178129-6
(D-3200M 6-position receptacle housing XY)
Contact specifications
(Tyco Electronics AMP)
1-175218-2
(D-3 receptacle contact L)
Applicable wire
size
0.5 to 1.25 mm
2
Insulation
external
diameter
φ1.8 to 2.8 mm
The following power and brake connector kit is available:
For power and brake
Connector kit specifications
(FANUC specification)
A06B-6114-K240
Contents of the connector kit
Receptacle housing(3-178129-6) × 1
Receptacle contact D-3 L (1-175218-2) × 6
The following dedicated tools are required for this connector.
Applicable contact Tyco Electronics AMP
specification
FANUC specification
Crimping tool D-3 contact size L 914596-3 A06B-6110-K220#D3L
Extractor D-3 contact 234168-1 A06B-6110-K220#D3R
NOTE
The contacts are of the type which crimps the
covering in addition to the wire. Follow the
dimension of the insulation part listed above. An
insulation of a diameter outside the above range
may be able to be connected depending on the wire
or tool, however. For details, contact the connector
manufacturer.