2.HOW TO USE SERVO MOTORS SPECIFICATIONS FOR THE βiS SERIES B-65302EN/01
- 22 -
2.2.3.6 Connectors on the cable side (for power and brake : models
β
ββ
β2is and β
ββ
β4is)
Dedicated connectors which are TÜV approved are available as the
connector for power for the β2is and β4is. These connectors differ
from the conventional α series connectors in connectors and contacts.
The following subsection describes the specifications as a connector
kit. These connectors are dripproof when engaged.
To connect the cable, a dedicated crimping tool must be used.
Consider crimping and cable clamp. Also note that there are
restrictions.
For power
Straight type
(standard)
1473063-2 (Tyco Electronics AMP)
A06B-6114-K220#S (FANUC specification)
Connector kit specifications
(Including the contact)
Elbow type
(CAUTION 1)
1473393-2 (Tyco Electronics AMP)
A06B-6114-K220#E (FANUC specification)
Applicable wire size
(CAUTION 2)
AWG#18 to 16
Insulation external diameter
(CAUTION 3)
φ1.8 to 2.8
Compatible cable O.D.
(CAUTION 4)
φ9.9 to 11.4
Crimping tool
(CAUTION 5)
91579-1 (Tyco Electronics AMP)
A06B-6114-K221#C (FANUC specification)
Extractor
(CAUTION 5)
1463329-1 (Tyco Electronics AMP)
A06B-6114-K221#R (FANUC specification)
CAUTION
1 For the elbow type, a cable juts from the motor in a vertical direction. To connect a
conduit hose to the connector, use the elbow type. (The straight type cannot be used
due to dimensional restrictions.)
2 The contact is of the crimp type. Be careful of the applicable wire.
3 The crimping contact crimps the covering in addition to the wire. Follow the
dimensions listed above.
An insulation of a smaller diameter may be able to be connected by a wire or tool,
however. For details, contact Tyco Electronics AMP.
4 To satisfy the TÜV-approved and waterproof performance, a cable of an outside
diameter within the applicable cable clamp range of φ9.9 to φ11.4 must be used.
5 Dedicated tools are required for crimping and extracting the contact. Keep them on
hand when required.