Changing of the gas piping for Fanuc Laser C1000-Model E Additional Manual Page 1

Additional Manual
TECHNICAL REPORT (MANUAL) NO. TML01/006E
Date: Aug/16 /2001
General Manager of
LASER Laboratory
Changing of the gas piping for FANUC LASER C1000-MODEL E
1. Communicate this report to:
Your information only
GE Fanuc-N, GE Fanuc-E
FANUC Robotics
MILACRON
Machine tool builder
Sales agency
End user
2. Summary for Sales Documents
3. Notice
We changed the specification of a fitting connecting between an oscillator and an exhaust
pump, and used on the exhaust pump.
We would notice a new gas piping method for FANUC LASER C1000-MODEL E.
4. Attached Document
Drawing
NO.
A-81053E-015
(1/2-2/2)
IDE
Original section of issue
Department
Manager
Section
Manager
Person in
Charge
FANUC

Contents Summary of Changing of the gas piping for Fanuc Laser C1000-Model E Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) NO. TML01/006E Date: Aug/16 /2001 General Manager of LASER Laboratory Changing of the gas piping for FANUC LASER C1000-MODEL E 1. Communicate this report to: 〇 Your information only 〇 GE Fanuc-N, GE Fanuc-E FANUC Robotics MILACRON Machine tool builder Sales agency End user
  • Page 2Changing of gas piping for FANUC LASER C1000-MODEL E 【Overview】 In order to improve an operation, we changed a specification of a fitting connecting between an oscillator and an exhaust pump, used on the exhaust pump side. We would announce a new gas piping method as follow. Old method New method Ti
  • Page 3【Note】 Clean the seal surface, and check that there are no scratches on the surface. The torque tightening the "NEW1" is about 45[N m] The torque tightening the "NEW2" is about 40[N m] (These data are adapted only to the first tightening) Tightening with a quite weak torque, it would make a seal per