B-63192EN/03 8.LASER OUTPUT CONTROL
- 27 -
8.1 C AND Y SERIES LASER CONTROL
The 16i-LA supports laser output control functions for the CO
2
laser
(C series) and continuous-output YAG laser (Y series). When the
shutter is open, and the piercing command (G24) or a cutting feed
command (G01, G02, G03, or G12) is executed, the laser beam is
turned on. When the command execution ends, the laser beam is
turned off. G01, G02, G03, G12, and G24 are generically called laser