B-63192EN/03 10.FUNCTION FOR THREE-DIMENSIONAL PROCESSING SYSTEM
- 73 -
(a) Mirror image conversion
G98 P0 X_Y_Z_ ; Reference point
G98 Q0 X_Y_Z_ ; Target point
(b) Three-dimensional movement conversion
G98 P1 X_Y_Z_ ; Reference point
G98 P2 X_Y_Z_ ; Reference point
G98 P3 X_Y_Z_ ; Reference point
G98 Q1 X_Y_Z_ ; Target point
G98 Q2 X_Y_Z_ ; Target point
G98 Q3 X_Y_Z_ ; Target point
(4) Operation mode
G98 can be executed in either memory of MDI mode.
(5) Discontinuing movement and laser beam status
Suppose the program shown below is to be executed. The
machine stops and the laser beam is turned off, at a shift from
move command group (a) to move command group (b) and at a
shift from move command group (b) to move command group
(c).
G98 Q0 ; or Q3 ;
Move command group (a)
G99 ;
Move command group (b)
Move command group (c)
Three-dimensional
function enabled
(6) Compound command
Mirror image conversion and movement conversion can be
specified simultaneously. For example, when mirror image
conversion is specified after movement conversion, both
conversion types are enabled provided that the former type has
not been canceled.
The cancel command G99 cancels all conversion commands. If
it is necessary to cancel one type of conversion in a compound
command, first cancel the whole compound command using the
G99, then specify the necessary conversion type again.
When the proximity point search signal is turned off, and a cycle
start is requested, machining begins at that point.