4. DESCRIPTION OF PARAMETERS
B–63090EN/02
18
0133 Baud rate (when the I/O CHANNEL is set to 3)
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
Set the baud rate of the input/output device used when the I/O CHANNEL
is set to 3 according to the table 4.2 (c).
Valid data range: 1 to 15 (up to a baud rate of 86400 bps) for the RS–422
interface or 1 to 12 (up to a baud rate of 19200 bps) for the RS–232C
interface.
Table 4.2.5 Baud Rate Settings
Set value Baud rate (bps)
1
2
3
4
5
6
Set value Baud rate (bps)
9
10
11
2400
9600
12
14
38400
76800
13
50
100
110
150
200
300
600
1200
7
8
14
4800
19200
86400
#7
0134
#6 #5
CLK
#4
NCD
#3 #2
SYN
#1
PRY
#0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
PRY Parity bit
0: Not used
1: Used
SYN Reset/alarm in protocol B
0: Not reported to the host
1: Reported to the host with SYN and NAK codes
NCD CD (signal quality detection) of the RS–232C interface
0: Checked
1: Not checked
CLK Baud rate clock when the RS–422 interface is used
0: Internal clock
1: External clock
NOTE
When the RS–232C interface is used, set this bit to 0.