B–63090EN/02
4. DESCRIPTION OF PARAMETERS
261
6030 M code that calls the program entered in file
[Data type] Byte
[Valid data range] 0, and 1 to 255
This parameter sets an M code that calls the program entered in a file.
NOTE
The M code is judged to be M198 when zero is specified as
the setting value.
6033 M code that validates a custom macro interrupt
6034 M code that invalidates a custom macro interrupt
[Data type] Byte
[Valid data range] 0 to 255
These parameters set the custom macro interrupt valid/invalid M codes.
NOTE
These parameters can be used when MPR, #4 of parameter
No.6003, is 1. M96 is used as a valid M code and M97 is
used as an invalid M code when MPR is 0, irrespective of the
state of this parameter.
6050 G code that calls the custom macro of program number 9010
6051 G code that calls the custom macro of program number 9011
6052 G code that calls the custom macro of program number 9012
6053 G code that calls the custom macro of program number 9013
6054 G code that calls the custom macro of program number 9014
6055 G code that calls the custom macro of program number 9015
6056 G code that calls the custom macro of program number 9016
6057 G code that calls the custom macro of program number 9017
6058 G code that calls the custom macro of program number 9018
6059 G code that calls the custom macro of program number 9019
[Data type] Word
[Valid data range] 1 to 999
These parameters set the G codes that call the custom macros of program
numbers 9010 through 9019.
NOTE
Setting value 0 is invalid. No custom macro can be called by
G00.