FANUC Series 16i/18i/21i Additional Manual Page 1

Additional Manual
FANUC Series 16i /18i /21i – A/B
Expansion of the Setting Range of Signals
On Operation History
Specifications
CONTENTS
1. GENERAL................................................................................................................................................................2
2. P
ARAMETERS..........................................................................................................................................................3
3. A
LARM AND MESSAGE..............................................................................................................................................7
Edit
Apprv.
Desig.
Sheet
TITLE
Draw
No.
Date
Design
Descri
p
tion
Date
FANUC Series 16i/18i/21i–A/B
Expansion of the setting range of signals on
o
p
eration histor
y
S
p
ecifications
A-90015E
2002.7.31
1
/
7

Contents Summary of FANUC Series 16i/18i/21i Additional Manual

  • Page 1FANUC Series 16i /18i /21i – A/B Expansion of the Setting Range of Signals On Operation History Specifications CONTENTS 1. GENERAL ................................................................................................................................................................2 2. PARA
  • Page 21. General The setting ranges of signals are expanded on the operation history function. Expansion signals are as follows. Expansion range of signals X0200 to X0327 For I/O Link 2 channel Y0200 to Y0327 For I/O Link 2 channel G0256 to G0511 G1256 to G1511 *For PMC-SB6, SB7 G2256 to G2511 Actual max
  • Page 32. Parameters #7 #6 #5 #4 #3 #2 #1 #0 3106 OHS OHP [Data type] Bit OHP The operation history screen is : 0 : Not displayed. 1 : Displayed. OHS Operation history sampling is : 0 : Performed. 1 : Not performed. #7 #6 #5 #4 #3 #2 #1 #0 3112 OPH [Data type] Bit OPH The operation history function is 0 :
  • Page 4#7 #6 #5 #4 #3 #2 #1 #0 3206 PHS [Data type] Bit PHS 0 : Operation history signal selection is not linked to parameters. Addition or deletion of the operation history signal selection is done on the operator history signal selection screen. Even if the parameter Nos.12801 ~ 12820, 12841 ~ 12860 or 1
  • Page 512801 Operation history signal selection signal type (No. 01) 12802 Operation history signal selection signal type (No. 02) 12803 Operation history signal selection signal type (No. 03) . . . . 12820 Operation history signal selection signal type (No. 20) [Data type] Byte [Valid data range] 0 to 12
  • Page 612841 Operation history signal selection address (No. 01) 12842 Operation history signal selection address (No. 02) 12843 Operation history signal selection address (No. 03) . . . . 12860 Operation history signal selection address (No. 20) [Data type] Word [Valid data range] 0 to 511 Specify the sig
  • Page 73. Cautions The actual maximum setting value which is expanded signals on the operation history depends on the PMC system. TITLE FANUC Series 16i/18i/21i–A/B Expansion of the setting range of signals on operation history Specifications Draw No. A-90015E Edit Date Design Description Sheet 7/7 Date 20