#7 #6 #5 #4 #3 #2 #1 #0
3206 PHS
[Data type] Bit
PHS 0 : Operation history signal selection is not linked to parameters.
Addition or deletion of the operation history signal selection is done on the operator
history signal selection screen. Even if the parameter Nos.12801 ~ 12820, 12841 ~
12860 or 12881 ~ 12900 are changed, the operation history signals are not
affected.
1 :Operation history signal selection is linked to parameters.
The operation history signal selection can be done on the operator history signal
selection screen or the parameter setting screen.
Note
When this parameter is changed to 1 from 0, the signal data are
transferred to the parameter Nos.12801 ~ 12820, 12841 ~ 12860 and
12881 ~ 12900.
Edit
Apprv.
Desig.
Sheet
TITLE
Draw
No.
Date
Design
Descri
tion
Date
FANUC Series 16i/18i/21i–A/B
Expansion of the setting range of signals on
o
eration histor
S
ecifications
A-90015E
2002.7.31
4
7