Fanuc C-Executer Operating Manual
B-62443EN-3/03E
- 906 -
FANUC Series 16/18 C Executor
5.4 Setting parameters for CNC
=============================
Parameters related to C Executor
Descriptions of parameters
Data
Data number #7 #6 #5 #4 #3 #2 #1 #0
+--------+ +------+------+------+------+------+------+------+------+
| 8650 | | | | | CKM | DMA | EKY | CNA | RSK |
+--------+ +------+------+------+------+------+------+------+------+
Data format : Bit type
RSK Specifies whether the key code is transferred to application
when a reset key is pushed.
0 : not transferred
1 : transferred
CNA Specifies whether the screen is changed to NC alarm screen
when NC alarm is generated during the user screen by C
Executor is displayed.
0 : the change whether automatically or not is decided by
the value of parameter No.3111#7 NPA.
1 : Do not change without relation of the value of parameter
No. 3111#7 NPA
EKY Expanded parts (9 through 11 lines) of MDI key are
0 : not read.
1 : read.
DMA The transmission of RS-232C is executed
0 : without DMA transfer.
1 : with DMA transfer.
CKM The bit-matrix of MDI key is
0 : not transferred to NC side.
1 : transferred to NC side.
Set this bit to 1 only when it is specially need to read
directly the bit-matrix in NC side. Set it to 0 normally.
(note) The change of the set data becomes effective after the next
power on.