Concerning addition of the Changing Active Offset Value with Manual Move Supplement to Manual Page 13

Supplement to Manual
Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
10
/
10
Date
Design
Descri
tion
Date
FANUC Series16i/18i/21i–MA/MB
Changing Active Offset Value
with Manual Move.
02 030205 Overall revision
001106 S. Isohata E. Genma
A-78535E
#7 #6 #5 #4 #3 #2 #1 #0
3409 CFH
[ Input type ] Parameter input
[ Data type ] Bit
CFH When bit 6(CLR) of parameter No.3402 is 1, the reset button on
the MDI panel, the external reset signal, the reset and rewind
signal, or emergency stop will,
0: Clear F codes, H codes, D codes.
1: Not clear F codes, H codes, D codes.
5. Restriction
1. It is not possible to change the offset value in modes other than the manual handle feed,
incremental feed, and jog feed by this function. It is not possible to change it by another
function of the three-dimensional handle feed, the manual numerical command, the PMC
axis control etc. even if in the above-mentioned mode in case of using this function.
2. It is not possible to change the offset value by this function in the manual reference point
return mode.
3. The offset value of the rotation axis cannot be changed by this function.
6. Caution
1. The changed tool compensation is managed according to parameter EVO(No.5001#6),
EVR(No.5001#4).
2. The tool length compensation and cutter compensation can be changed for the linear
axes. It is possible to forbid changing the offset value of any axis by interlocking (IT1 to
IT8 (G130#0 to #7)) the axis with the PMC (ladder).

Contents Summary of Concerning addition of the Changing Active Offset Value with Manual Move Supplement to Manual

  • Page 1TECHNICAL REPORT NO.TMN 03/011E Date : Feb.06.’03 General Manager of Software Development Center FANUC Series 16i/18i/160i/180i/160is/180is - MA OPERATOR’S MANUAL FANUC Series 16i/18i/160i/180i - MB OPERATOR’S MANUAL FANUC Series 18i/180i/180is - MB OPERATOR’S MANUAL FANUC Series 21i/210i/210is - MA
  • Page 2FANUC Series 18i/180i/180is - MB OPERATOR’S MANUAL FANUC Series 21i/210i/210is - MA OPERATOR’S MANUAL FANUC Series 21i/210i - MB OPERATOR’S MANUAL Concerning addition of the Changing Active Offset Value with Manual Move 1.Type of applied technical documents FANUC Series 18i/180i/180is - MB OPERATOR’
  • Page 3• Adding “FANUC Series 16i /18i /21i – MA / MB Changing Active Offset Value with Manual Move (A-78535E)” to this description (Attached papers) FANUC Series 16i /18i /21i – MA / MB Changing Active Offset Value with Manual Move (A-78535E) 18i/180i/180is - MB 21i/210i – MA/MB OPERATOR’S MANUAL TITLE Co
  • Page 4FANUC Series 16i /18i /21i – MA/MB Changing Active Offset Value with Manual Move Index 1. Outline ........................................................................................................................... 2 2. Explanation..............................................................
  • Page 51. Outline If you want to perform roughing or semi-finishing with a single tool, you may fine-adjust the tool length compensation or cutter compensation. Moreover, you may want to fine-adjust the setting of the workpiece origin offset that was already set up. This function can change the offset (suc
  • Page 6Example The compensation value set at Z-axis of the offset number 10 becomes 54.700 + (-2.583) = 52.117 mm under the following conditions: • Specified H code: H10 • Value set at Z-axis of the offset number 10: 54.700 mm • Amount of movement caused by manual feed along the Z-axis: -2.583 mm 2.4 Chang
  • Page 7Example Assume the following conditions: • Specified workpiece coordinate system: G56 • G56 workpiece origin offset (X-axis): 50.000 • G56 workpiece origin offset (Y-axis): -60.000 • G56 workpiece origin offset (Z-axis): 5.000 • G56 workpiece origin offset (C-axis): 180.000 • Amount of manual feed-b
  • Page 82.7 Presetting the relative position indicator Setting parameter APL (No. 3115#5) to 1 can preset the relative position indicator (counter) to 0 automatically when active offset change mode is selected. In this case, performing manual feed until the relative position indicator (counter) becomes 0 ca
  • Page 93. Signal Active offset change mode signal CHGAO [Classification] Input signal [Function] This signal selects the manual feed-based active offset change mode. [Operation] Setting this signal to "1" selects the manual feed-based active offset change mode. • Automatic operation is at pause or
  • Page 10Signal addresses • Parameter No.5040#2(MOP)=0 #7 #6 #5 #4 #3 #2 #1 #0 G0297 AOFS2 AOFS1 CHGAO #7 #6 #5 #4 #3 #2 #1 #0 F0297 MCHAO • Parameter No.5040#2(MOP)=1 #7 #6 #5 #4 #3 #2 #1 #0 G0203 AOFS2 AOFS1 CHGAO #7 #6 #5 #4 #3 #2 #1 #0 F0199 MCHAO The following timing chart shows how the input and signal
  • Page 114. Parameter #7 #6 #5 #4 #3 #2 #1 #0 3115 APL [ Input type ] Parameter input [ Data type ] Bit axis APL Specifies whether to preset the relative position indicator automatically when the manual feed-based active offset change mode is selected, as follows: 0: Do not preset. 1: Preset. This signal is
  • Page 12#7 #6 #5 #4 #3 #2 #1 #0 5041 AOF [ Input type ] Parameter input [ Data type ] Bit AOF When the manual feed-based active offset change mode is selected in a reset state or a cleared state, the tool compensation: 0: Can be changed 1: Cannot be changed However, even if “1” is set in parameter CLR(No.34
  • Page 13#7 #6 #5 #4 #3 #2 #1 #0 3409 CFH [ Input type ] Parameter input [ Data type ] Bit CFH When bit 6(CLR) of parameter No.3402 is 1, the reset button on the MDI panel, the external reset signal, the reset and rewind signal, or emergency stop will, 0: Clear F codes, H codes, D codes. 1: Not clear F codes