M. PARAMETERS
B–66102E/10
APPENDIX
210
Bit No.
#7 #6 #5 #4 #3 #2 #1 #0Address
9000 L2R MKG RSC EXS STP NDP SQN
SQN = 1 : Displays program number of recorded program and
sequence number during execution of a recorded program.
= 0 : Displays program number and sequence number of called
user program during execution of a recorded program.
NDP = 1 : Displays variables for P-CODE program.
= 0 : Does not display variables for P-CODE program.
STP = 1 : Stops execution of conversational macro program. (”1” is
set by break function automatically)
= 0 : Execute the conversational macro program.
EXS = 1 : Execute macro statement till the next NC statement has
come with feed hold, during macro statement execution at
execution level.
= 0 : Stop if feed hold acts, during macro statement execution at
execution level.
RSC = 1 : Common variables #100-#149 are cleared to <vacant> if NC
is reset.
= 0 : Common variables #100-#149 do not clear to <vacant> if
NC is reset.
MKG : Be sure to set to 0.
L2R = 1 : Does not display conversational / auxiliary macro and screen
during execution macro operation.
= 0 : Display conversational / auxiliary macro and screen during
execution macro operation.
Address
9002 Conversational macro break program number
9003 Conversational macro break sequence number
M.2.2
Executer Parameter