4. FUNCTIONS
B–66102E/10
20
NOTE
1 For the 21-TB (Controller A), always specify 128 KB.
2 For the Series 16, a 128-KB ROM-format file cannot be
specified.
3 For the 21-MB or 21-TB (Controller B), no more than 1.0 MB
can be specified.
4 For the 0i–A, no more than 512 KB can be specified.
D Series 15i–A
Bit No.
#7 #6 #5 #4 #3 #2 #1 #0Address
8500 R10 R05
Compile
parameter
R10 R05
1.0MB 1 0
512KB 0 1
256KB 0 0
NOTE
For the Series 15i–A, only the combinations given in the
table above are possible.
(6) Error messages
1) When the Series 16i/18i/21i–A Macro library is linked using a
macro linker (MLINK.EXE) of MACRO COMPILER version
03.2 or earlier, the following error will occur:
ERROR: Executer#1 is not specified
2) When the SYSTEM keyword is not specified, the following error
will occur:
ERROR: Can not find SYSTEM define