B–66102E/10
M. PARAMETERS
APPENDIX
211
Bit No.
#7 #6 #5 #4 #3 #2 #1 #0Address
9010 MA8 MA7 MA6 MA5 MA4 MA3 MA2 MA1
MA1 = 1 : Masks a first axis address macro call.
= 0 : Does not mask a first axis address macro call.
MA2 = 1 : Masks a second axis address macro call.
= 0 : Does not mask a second axis address macro call.
MA3 = 1 : Masks a third axis address macro call.
= 0 : Does not mask a third axis address macro call.
MA4 = 1 : Masks a fourth axis address macro call.
= 0 : Does not mask a fourth axis address macro call.
MA5 = 1 : Masks a fifth axis address macro call.
= 0 : Does not mask a fifth axis address macro call.
MA6 = 1 : Masks a sixth axis address macro call.
= 0 : Does not mask a sixth axis address macro call.
MA7 = 1 : Masks a seventh axis address macro call.
= 0 : Does not mask a seventh axis address macro call.
MA8 = 1 : Masks an eighth axis address macro call.
= 0 : Does not mask an eighth axis address macro call.
NOTE
When compilation parameter bit 4 of No. 9005 (AXCLS) is
set to 1, MA1 masks O9031, MA2 masks O9032, MA3
masks O9033, and so on.
Bit No.
#7 #6 #5 #4 #3 #2 #1 #0Address
9011 MTC
MTC = 1 : Masks a T code execution macro call.
= 0 : Does not mask a T code execution macro call.