EDT
DATE
FANUC Series 16i/18i
Spindle Synchronous Control with
any spindle
A-63502E
10/11
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
6. Spindle Tuning Screen
In spindle synchronous control mode, the following information is displayed on spindle
tuning screen.
MOTOR
SPINDLE
POS ERR S
SYN.ERROR
The screen can be switched for each spindle by pressing PAGE key.
“MOTOR” shows motor speed.
“SPINDLE” shows spindle speed.
“POS ERR S” shows position errors of the currently displayed spindle.
“SYN.ERROR” shows synchronous errors(absolute value) if the spindle is specified as
slave.
7. Alarm
194
SPINDLE COMMAND IN SYNCHRO-MODE
A contour control mode, spindle positioning(Cs-axis) mode, or rigid tapping
mode was specified during spindle synchronous control mode.
Correct the program so that spindle synchronous control mode is released in
advance.
8. Notes
NOTE1) This function is available only for serial spindles.
NOTE2) This enhancement of the function requires PMC-SB6.
NOTE3) On the multi path control, spindle synchronous control can be used only between
the spindles in the same path.
(2)