4. Parameters
#7 #6 #5 #4 #3 #2 #1 #0
3704 SSS
Data type : Bit
SSS Enhanced Spindle Synchronous Control is:
0: enabled
1: disabled
You can select any pair for Spindle Synchronous Control out of 1st to 4th
spindles.
Master for each slave is specified in the parameters No.4831 to 4834.
NOTE1) It is available only for serial spindles.
NOTE2) When this parameter is set, power must be turned off before operation
is continued.
4831
Master spindle for 1st spindle
4832
Master spindle for 2nd spindle
4833
Master spindle for 3rd spindle
4834
Master spindle for 4th spindle
Data type : Byte
Specify master spindle for each slave spindle.
EXAMPLE) When specifying 2nd spindle as master and 3rd as slave, the
setting of the parameters is as follows.
No.4831 = 0
No.4832 = 0
No.4833 = 2
No.4834 = 0
NOTE1) It is available only when the parameter SSS(No.3704#4) is 1.
NOTE2) When this parameter is set, power must be turned off before operation
is continued.