EDT
DATE
FANUC Series 16i/18i
Spindle Synchronous Control with
any spindle
A-63502E
3/11
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
3. Signals
Spindle synchronization signals
SPSYC1 to SPSYC4<G288.0 to G288.3>
[Classification] Input signal
[Function] Enable Spindle Synchronous Control.
[Operation] When SPSYC1 is 1, 1st spindle will be synchronized as slave.
When SPSYC2 is 1, 2nd spindle will be synchronized as slave.
When SPSYC3 is 1, 3rd spindle will be synchronized as slave.
When SPSYC4 is 1, 4th spindle will be synchronized as slave.
These signals are available only when the parameter SSS(No.3704#4) is 1.
Master for each slave is specified in the parameters No.4831 to 4834.
Spindle phase synchronization signals
SPPHS1 to SPPHS4<G289.0 to G289.3>
[Classification] Input signal
[Function] Enable spindle rotation phase synchronization.
[Operation] When SPPHS1 turns 1 (from 0), phase synchronization will be
performed to the synchronous pair containing 1st spindle as slave.
When SPPHS2 turns 1 (from 0), phase synchronization will be
performed to the synchronous pair containing 2nd spindle as slave.
When SPPHS3 turns 1 (from 0), phase synchronization will be
performed to the synchronous pair containing 3rd spindle as slave.
When SPPHS4 turns 1 (from 0), phase synchronization will be
performed to the synchronous pair containing 4th spindle as slave.
These signals are available only when the parameter SSS(No.3704#4) is 1.
Phase synchronization shift amount is specified in the parameter No.4034.