10
13
Si
nature Description
1998/09/21
FS16/18-MC , FS16i
18i-M
Tool Life Management B
A-63526E
Title
Drawin
No.
Edit Data
3.5. Parameter
data
No. #7 #6 #5 #4 #3 #2 #1 #0
GRP Data for the notice signal (TLCHB)is used by
0 : parameter No.6844,No.6845
1: data to be set for each group
ARL The notice signal (TLCHB) is
0: output each tool
1: output last tool in the group
Note)This parameter is effective when parameter No.6802#3 is 1.
RMT The signal (TLCHB) is turned off,
0 : when value of‘LIFE-COUNT' is larger than value of remaining tool life
data (“Less” type)
1 : when value of‘LIFE-COUNT' is not equal value of remaining tool life
data (“Equal” type)
3.6. Signal
No. #7 #6 #5 #4 #3 #2 #1 #0
TLCHB
The signal (TLCHB) is turned on,
(1) when value of‘LIFE-COUNT' is smaller than value of remaining tool life
data (“Less” type)
(2) when value of‘LIFE-COUNT' is equal value of remaining tool life
data (“Equal” type)
RMT ARL GRP
6802
F0064
TLCHB