FANUC Series 16/18 MC 16i/18i MA toollife management b Additional Manual Page 3

Additional Manual
ページ
ページ
ページ
ページ
2
/
13
Si
g
nature Description
1998/09/21
FS16/18-MC , FS16i
/
18i-M
A
Tool Life Management B
A-63526E
Title
Drawin
g
No.
Edit Data
1. Tool life value expansion (999999
999999999999
999999times/100000
/100000/100000
/100000minutes
1.1.General
Though the maximum value of the tool life could be set 65535 times or 4300 minutes by
the tool life management, the value is possible to expand for 999999 times or 100000
minutes by using the option of tool life management B.
1.2.Setting method
As for the display of the tool life management and the extended tool life management, the
value of life and count become 6 digits. (Refer to 4. Display)
The method of setting the life value is the same as the past. (However, life data can set
1-999999 times or 1-100000 minutes)
The life data can not set to exceed maximum value of each life count type. When the life
data is specified larger than the maximum value, PS158 alarm is generated.
(1) The data setting by programming
Example) When 999999 times is set to the tool life value in the group No. 1
G10 L3 ;
P1 L999999 ;
T01 ;
G11 ;
M02 ;
G10 L3 → Start of setting tool life data
P__    → Group No. (1-maximum group No.)
L__    → Tool lifefrequency1-999999time1-100000
T__    → Tool No.
G11    → End of setting tool life data
Maximum group No. : As follows, maximum group No. is changed by parameter No. 6800#0(GS1) and
#1(GS2)
standard 512 pairs
No. of groups No. of tools No. of groups No. of tools
16 16 64 32
32 128 16
64 256
128 512

Contents Summary of FANUC Series 16/18 MC 16i/18i MA toollife management b Additional Manual

  • Page 1FANUC Series 16/18-MC FANUC Series 16i/18i-MA Tool Life Management B Specifications Software Software Software Laboratory Laboratory FLB1 Section FLB1 Section Title FS16/18-MC , FS16i/18i-MA Tool Life Management B Drawing No. A-63526E ページ Edit Data Signature Description 0/13 1998/09/21 DS0000-00 1版
  • Page 2FANUC Series 16/18-MC FANUC Series 16i/18i-MA Tool Life Management B Specifications 1.TOOL LIFE VALUE EXPANSION (999999TIMES/100000MINUTES) ........................................... 2 1.1. GENERAL .....................................................................................................
  • Page 31. Tool life value expansion (999999 999999times/100000 999999 /100000minutes) /100000 ) 1.1.General Though the maximum value of the tool life could be set 65535 times or 4300 minutes by the tool life management, the value is possible to expand for 999999 times or 100000 minutes by using the option
  • Page 42. Arbitrary tool group number setting 2.1.General By using this function (parameter No.6802#5), it is possible to specify the group by using an arbitrary T code instead of the group by using T code of tool life management ignore No. + Group No. 2.2.Setting method (1)The data setting by programming
  • Page 5Note 1) If the arbitrary group number is set to the same number at other groups, PS158 alarm is generated. Note 2) Please set arbitrary group number (1-99999999). If the arbitrary group number is not set, PS149 alarm is generated. Note 3) It is not possible to set to the arbitrary group number by ex
  • Page 62.3. Use method The arbitrary group number is specified same as usual tool life management with T code. But tool life management ignore number (parameter No.6810) cannot be used. Example) When tool of the group is used after arbitrary group number 12345 is set to group No. 1 O0001; T12345; → tool se
  • Page 73. Tool life notice signal 3.1.General When‘Tool life value(LIFE)-life counter value(COUNT)' reaches the value that is the remainder of tool life until selecting a new tool for each groups, signal (TLCHB) is output to PMC. 3.2.Setting method The remainder of tool life until selecting a new tool (rem
  • Page 8(2)The data setting by extended tool life management (data editing screen for the group). It is possible to edit the remaining tool life by using the extended tool life management (data editing screen for the group). The edit method is done by the same method as other items. That is, The cursor is m
  • Page 93.3. Use method When the tool counter is added 1 and ‘Tool life value (LIFE)-life counter value (COUNT)' reaches the value (remaining tool life value), signal (TLCHB) is output to PMC. Example) It is assumed that group No. 1 is in the state when life is controlled by the frequency as follows. EDIT L
  • Page 103.4.Note Note 1) The parameter of the extended tool life management is necessary. Note 2) The signal is turned on as follows. (1) When value of‘LIFE-COUNT' and value of remaining tool life of each group is the same. → "Equal" type (2) When value of‘LIFE-COUNT' is smaller than value of remaining tool
  • Page 113.5. Parameter data No. #7 #6 #5 #4 #3 #2 #1 #0 6802 RMT ARL GRP GRP Data for the notice signal (TLCHB)is used by 0 : parameter No.6844,No.6845 1: data to be set for each group ARL The notice signal (TLCHB) is 0: output each tool 1: output last tool in the group Note)This parameter is effective when
  • Page 124. Display The group number is displayed 8 digits, the count and life data number is displayed 6 digits in the tool life screen and extended tool life screen. 【tool life management display】 TOOL LIFE DATA : O0001 N00000 NXT 99999999 USE 00000001 SLCT 00000001 001: 00000001:C LIFE 100000 COUNT 100000
  • Page 13【extended tool life management display(notice signal)】 EDIT LIFE DATA GRP:99999999 TYPE :2(1:C 2:M) USE GROUP: 00000003 LIFE :100000 SELECTED GROUP: 00000002 COUNT:100000 REST COUNT : 100000 NO. STATE T-CODE H-CODE D-CODE 01 * 00000001 002 003 02 # 00000004 005 006 03 @ 00000007 008 009 04 * 0000001
  • Page 145. Comparisons between Tool Life Management and Tool Life Management B Tool life management B is upper compatible with tool life management. function tool life tool life note management B management extended tool life management 〇 〇 6801#6 tool life count override 〇 〇 6801#2 life count by 1 sec 〇 〇