ページ
ページ
ページ
ページ
2
13
Si
nature Description
1998/09/21
FS16/18-MC , FS16i
18i-M
Tool Life Management B
A-63526E
Title
Drawin
No.
Edit Data
1. Tool life value expansion (999999
999999999999
999999times/100000
/100000/100000
/100000minutes)
))
)
1.1.General
Though the maximum value of the tool life could be set 65535 times or 4300 minutes by
the tool life management, the value is possible to expand for 999999 times or 100000
minutes by using the option of tool life management B.
1.2.Setting method
As for the display of the tool life management and the extended tool life management, the
value of life and count become 6 digits. (Refer to 4. Display)
The method of setting the life value is the same as the past. (However, life data can set
1-999999 times or 1-100000 minutes)
The life data can not set to exceed maximum value of each life count type. When the life
data is specified larger than the maximum value, PS158 alarm is generated.
(1) The data setting by programming
Example) When 999999 times is set to the tool life value in the group No. 1
G10 L3 ;
P1 L999999 ;
T01 ;
G11 ;
M02 ;
G10 L3 → Start of setting tool life data
P__ → Group No. (1-maximum group No.)
L__ → Tool life(frequency:1-999999/time:1-100000)
T__ → Tool No.
G11 → End of setting tool life data
Maximum group No. : As follows, maximum group No. is changed by parameter No. 6800#0(GS1) and
#1(GS2)
(standard) (512 pairs)
No. of groups No. of tools No. of groups No. of tools
① 16 16 ① 64 32
② 32 8 ② 128 16
③ 64 4 ③ 256 8
④ 128 2 ④ 512 4