6
13
Si
nature Description
1998/09/21
FS16/18-MC , FS16i
18i-M
Tool Life Management B
A-63526E
Title
Drawin
No.
Edit Data
3. Tool life notice signal
3.1.General
When‘Tool life value(LIFE)-life counter value(COUNT)' reaches the value that is the
remainder of tool life until selecting a new tool for each groups, signal (TLCHB) is output to
PMC.
3.2.Setting method
The remainder of tool life until selecting a new tool (remaining tool life) is set by program
of G10 or the extended tool life management.
(1)The data setting by programming (G10 L3)
The remaining tool life is set by specifying P code that is commanded in the same block with R
code.
G10 L3 ;
P__ L__ R__ ;
T__ H__ D__ ;
T__ H__ D__ ;
P__ L__ ;
T__ H__ D__ ;
T__ H__ D__ ;
G11 ;
G10 L3 → Start of setting tool life data
P__ → Group No. (1-maximum group No.)
L__ → Tool life(frequency:1-999999/time:1-100000)
R__ → Remaining tool life(frequency:1-999999/time:1-100000)
T__ → Tool No.
H__、D__→ H,D code.
G11 → End of setting tool life data
Note 1) When the value of R is 0 or is omitted, life arrival notice signal (TLCHB) is not
output, because the remaining tool life value is set to 0.
Note 2) The remaining tool life value (value of R) cannot set larger value than life
(value of L). If that value is set, PS158 alarm is generated.
Note 3) Please do not apply decimal point or sign to the value of R. If that value is set,
PS006 alarm or PS007 alarm is generated.