FANUC Servo Amplifier ßi Series I/O Link Option Modification from I/O Link ß Additional Manual Page 21

Additional Manual
FANUC SERVO AMPLIFIER βi series I/O Link Option
Modification from I/O Link β
EDIT
DRAW. NO. CUST
TITLE
DESCRIPTION
DESIG.
DATE
A-79487E
21
/
23
01
04.03.15
SHEET
Newly designed
APPENDIXES
B PARAMETERS
B.7 DIGITAL SERVO STANDARD PARAMETER TABLE
March, 2004
Motor model
α1
5000i
β2
4000is
α2
5000i
β4
4000is
β8
3000is
β0.2
5000is
β0.3
5000is
α2
5000is
Motor
specification
0202 0061 0205 0063 0075 0210 0211 0212
Symbol Motor ID No. 252 253 255 256 258 260 261 262
BITPRM 19 00001000 00001100 00001000 00001100 00001100 00000000 00000000 00001000
PK1 70 620 360 760 400 650 123 210 530
PK2 71 -3034 -1920 -3743 -1920 -3831 -510 -970 -2543
PK3 72 -1256 -1237 -1283 -1253 -1299 -1069 -1146 -1251
PK1V 73 64 76 74 109 160 4 4 38
PK2V 74 -580 -681 -664 -984 -1441 -35 -32 -341
PK4V 75 -8235 -8235 -8235 -8235 -8235 -8235 -8235 -8235
PPMAX 76 21 21 21 21 21 21 21 21
PDDP 77 1894 1894 1894 1894 1894 1894 1894 1894
PVPA 78 0 -10250 -12298 -7694 -5140 0 0 -10250
PALPH 79 0 -1000 -1275 -2800 -3200 0 0 -2000
TQLIM 80 7282 6554 7282 7282 7282 7282 7282 7282
POVC1 81 32692 32652 32635 32532 32385 32583 32583 32650
POVC2 82 948 1455 1664 2945 4788 2312 2312 1475
POVCLMT 83 2812 4317 4941 8758 14271 6869 6869 4379
AALPH 84 20480 16384 12288 20480 16384 20480 20480 20480
DBLIM 85 0 0 0 0 0 0 0 0
MGSTCM 86 32 1048 32 780 1807 1 1 32
DETQLM 87 10260 11600 10280 7790 7930 7710 7700 8995
NINTCT 88 1188 1172 1276 796 1442 379 852 1137
MFWKCE 89 1667 2500 2000 3000 3500 0 3000 1000
MFWKBL 90 3858 3358 3862 3392 1298 0 3880 3851
EMFCMP 99 -5130 0 -10 0 -2570 0 0 0
PK2VAUX 101 0 0 0 0 0 0 0 0
TRQCST 112 72 119 109 146 226 7 14 117
MDLCST 115 1088 1856 951 1284 877 18132 19686 1844
PHDLY1 118 7690 7192 7693 8992 3858 7700 7695 7690
PHDLY2 119 12840 8990 12840 12864 8990 12825 12840 12840

Contents Summary of FANUC Servo Amplifier ßi Series I/O Link Option Modification from I/O Link ß Additional Manual

  • Page 1FANUC SERVO AMPLIFIER βi series I/O Link Option Modification from I/O Link β 1 OUTLINE............................................................................................................................. 2 2 DETAILED DESCRIPTION................................................................
  • Page 21 OUTLINE This technical report explains the modification from “FANUC SERVO MOTOR β series I/O Link Option” (for short, “I/O Link β”) to “FANUC SERVO AMPLIFIER βi series I/O Link Option” (for short, “I/O Link βi ”). About the contents except this technical report, please refer to “FANUC SERVO MOTOR
  • Page 3Ⅰ START-UP PROCEDURE 3 START-UP PROCEDURE 3.4 PARAMETER INITIALIZATION (1) Preparation prior to servo parameter initialization Before servo parameter initialization, check the following information: 1. Servo motor model (Example: β 8/3000is) 2. Amount of travel per motor revolution (Example: 10 mm/m
  • Page 44. Set the initialization bit DGPR to 0. b7 b6 b5 b4 b3 b2 b1 b0 No.12 DGPR When this bit is set to 0, a power-down request alarm (alarm No. 0) is issued. However, following procedure from 5 to 9 can be done. Start initialization It is not necessary to turn off CNC until 11. DGPR (b1) = 0 DGPR(b1) b
  • Page 56. Set CMR In parameter No.032, set coefficient for the command unit from the CNC system to the servo system. CMR = Command unit/detection unit When CMR is from 1 to 48 Setting = CMR x 2 When CMR is from 1/2 to 1/27 Setting = 1/CMR + 100 Usually, CMR = 1. So, set “2” in parameter No.032. 7. Set the
  • Page 69. Set the reference counter capacity. (Parameter No. 180) Set the reference counter capacity when performing a reference position return operation based on the grid method. Set the number of position pulses per motor revolution, or set that number divided by an integer. Example: αi pulse coders, se
  • Page 7Ⅰ START-UP PROCEDURE 4 OPERATION CHECK METHOD 4.1 CHECK PROCEDURE 1. Turn on the power. When the LED indicates data other than or Refer to the explanation of troubleshooting in Part III. 2. The LED indicates 3. The emergency stop state is released. The LED does not indicate Check the *ESP signal app
  • Page 8Table 4.1 LED Indications and Meanings LED State Description indication This indicates that control power (+24 Servo amplifier VDC) is supplied. No alarm is issued, unit not ready but the motor is not activated. This indicates that the motor is Servo amplifier activated, and that commands can now un
  • Page 9Ⅰ TROUBLESHOOTING AND COUNTERMEASURES 2 ALARM DISPLAY AND CORRESPONDING COUNTERMEASURES LED type Number Alarm type (Classification by Red LED) Or 000 to 299 Program or setting alarm 300 to 399 Pulse coder alarm Or 400 to 499 Servo alarm Same as PS alarm 500 to 599 Overtravel alarm Or - System alarm
  • Page 10No. LED display Description Countermeasure The reference position has not yet Set the reference position. been established. This occurs 224 only when the ZRTN bit of parameter No.001 is set to 0. Input data 1 or command is invalid. Check input data 1, specified with 250 a function code. Input data 2
  • Page 11Pulse coder alarms No. LED display Description Countermeasure A communication error (DTER) Check the continuity of the signal for the serial pulse coder was cable. If the cable is normal, the detected. pulse coder may be defective. 300 Turn the power off. If the alarm recurs when the power is reappl
  • Page 12No. LED display Description Countermeasure When the absolute pulse coder is Cause the motor to rotate through used, the motor has not yet more than one turn in jog feed 319 rotated through more than one mode, then turn the power off turn after the first power-up. then back on. The battery voltage of
  • Page 13Servo alarms No. LED display Description Countermeasure The servo motor has overheated. The motor operation condition may 400 (estimated value) be too severe. Check the operation condition. DRDY(Drive Ready signal) becomes 0. 401 The servo amplifier is not ready. SVM1-4i The cooling fins have The lo
  • Page 14No. LED display Description Countermeasure The servo position error in the Determine the mechanical cause of stop state is larger than the value the large position error. 410 specified in parameter No.110. If no mechanical cause is found, specify a larger value for the parameter. The servo position
  • Page 15No. LED display Description Countermeasure DC Link Over Voltage Alarm This alarm is issued when the DC has been issued. voltage of the main circuit power is too high. (1) When SVM1-4i or SVM1-20i is used, and a separate regenerative discharge unit is not used, check the specification to see if regen
  • Page 16No. LED display Description Countermeasure Inverter IPM Alarm has been issued. (1) Check whether the cooling fan is not stopped. (2) Check whether the motor is used within related current. (3) Check whether the temperature in locker is higher. Check the fin or filter in locker. (4) Check whether the
  • Page 17No. LED display Description Countermeasure DO Alarm is issued. Replace the servo amplifier unit. 418 The specified speed exceeds Re-examine the CMR and speed 423 32767000 detection units per settings. second. The cooling fan has stopped. This alarm is issued when the fan motor built into the servo a
  • Page 18Overtravel alarms No. LED display Description Countermeasure The positive stroke limit has been Check whether *+OT and *-OT are 500 exceeded. connected correctly. Check whether a correct move command The negative stroke limit has been is specified. Move the tool in the 501 exceeded. opposite directi
  • Page 19System alarms No. LED display Description Countermeasure An error was detected in the RAM Replace the servo amplifier unit. − write/read test at power-up. (External SRAM) A watchdog alarm 1 was issued. Turn the power off then back on. − If this alarm recurs, replace the servo amplifier unit. A watch
  • Page 20No. LED display Description Countermeasure An error was detected in the Replace the servo amplifier unit. − control circuit. A alarm for the servo amplifier Replace the servo amplifier unit. unit is issued. (General illegal − instruction) A alarm for the servo amplifier Replace the servo amplifier u
  • Page 21APPENDIXES B PARAMETERS B.7 DIGITAL SERVO STANDARD PARAMETER TABLE March, 2004 α1 β2 α2 β4 β8 β0.2 β0.3 α2 Motor model 5000i 4000is 5000i 4000is 3000is 5000is 5000is 5000is Motor 0202 0061 0205 0063 0075 0210 0211 0212 specification Symbol Motor ID No. 252 253 255 256 258 260 261 262 BITPRM 19 00001
  • Page 22α4 αC4 β12 α4 β22 αC8 α8 β0.4 Motor model 5000is 3000i 3000is 4000i 2000is 2000i 3000i 5000is Motor 0215 0221 0078 0223 0085 0226 0227 0114 specification Symbol Motor ID No. 265 271 272 273 274 276 277 280 BITPRM 19 00001000 00001000 00001100 00000000 00001100 00001000 00000000 00000000 PK1 70 420 1
  • Page 23αC30 Motor model 1500i Motor 0251 specification Symbol Motor ID No. 301 BITPRM 19 00001000 PK1 70 2238 PK2 71 -13330 PK3 72 -1347 PK1V 73 162 PK2V 74 -1451 PK4V 75 -8235 PPMAX 76 21 PDDP 77 1894 PVPA 78 -1545 PALPH 79 -1300 TQLIM 80 7282 POVC1 81 32632 POVC2 82 1704 POVCLMT 83 5058 AALPH 84 8192 DBL