11.APPLYCATION OF OTHER FUNCTIONS B-63494EN/02
- 184 -
11.2.3.2 Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G023
HNDLF
#7 #6 #5 #4 #3 #2 #1 #0
G101
*+ED28 *+ED27 *+ED26 *+ED25 *+ED24 *+ED23 *+ED22 *+ED21
G103 *-ED28 *-ED27 *-ED26 *-ED25 *-ED24 *-ED23 *-ED22 *-ED21
#7 #6 #5 #4 #3 #2 #1 #0
G107
*+ED38 *+ED37 *+ED36 *+ED35 *+ED34 *+ED33 *+ED32 *+ED31
G109 *-ED38 *-ED37 *-ED36 *-ED35 *-ED34 *-ED33 *-ED32 *-ED31
#7 #6 #5 #4 #3 #2 #1 #0
G118
*+ED8 *+ED7 *+ED6 *+ED5 *+ED4 *+ED3 *+ED2 *+ED1
G120 *-ED8 *-ED7 *-ED6 *-ED5 *-ED4 *-ED3 *-ED2 *-ED1
11.2.4 Parameters
#7 #6 #5 #4 #3 #2 #1 #0
1005 EDM EDP
[Data type] Bit axis
EDP The external deceleration signal in the positive direction of each axis
is:
0: Invalid for cutting feed
1: Valid for cutting feed
EDM The external deceleration signal in the negative direction of each axis
is:
0: Invalid for cutting feed
1: Valid for cutting feed
CAUTION
In rapid traverse, JOG feed, and manual handle
feed, external deceleration is enabled regardless of
the settings of bits 4 (EDP) and 5 (EDM) of
parameter No. 1005.
#7 #6 #5 #4 #3 #2 #1 #0
1406 EXD3 EXD2
[Data type] Bit
EXD2 External deceleration function setting 2 is:
0: Invalid
1: Valid
EXD3 External deceleration function setting 3 is:
0: Invalid
1: Valid