3.SAFETY FUNCTIONS B-63494EN/02
- 40 -
(16) Reading of programmable safe-related input signals
This function is equivalent to the pmc_rdsafeprgio() function.
[Input] Function code iodate[0] = 136
Data length iodata[2] = 0
Data number iodata[3] = 0
Data attribute iodata[4] = 0
[Output] Completion code iodata[1] = 0
Normal termination
6
The dual check safety option is not added.
Programmable safe-related input signals
iodata[5]
Higher byte: Programmable safe-related input signal 1
[DI+002]
Lower byte: Programmable safe-related input signal 2
[DI+003]
(17) Writing of programmable safe-related output signals
This function is equivalent to the pmc_wrsafeprgio() function.
[Input] Function code iodate[0] = 137
Data length iodata[2] = 1
Data number iodata[3] = 0
Data attribute iodata[4] = 0
Programmable safe-related output signals
( char )iodata[5]
[Output]Completion code iodata[1] = 0
Normal termination
6
The dual check safety option is not added.