B-63494EN/02 5.I/O SIGNALS
- 69 -
5.2 SIGNALS
Emergency stop signal
*ESP1 <X008#4>(<X000#7> for loader control), *ESPG <G008#4>,
*ESP2 <DI+000#0>
[Classification] Input signal
[Function] Stops machine movement immediately in an emergency.
[Operation] When emergency stop signal (*ESP) is set to 0, the CNC is reset, and
an emergency stop occurs. In general, emergency stop signal (*ESP)
is specified by the pushbutton switch B contact. When an emergency
stop occurs, the servo ready signal SA is set to 0.
When emergency stop signal (*ESP) is set to 0, the emergency stop
mode is set with the dual check safety function. In this mode, the
MCC contact state signal (*SMC) is checked. When *SMC = 0
(MCC-on state), the guard unlock signal (*LGD) is set to 0 (to disable
guard unlocking). When *SMC = 1 (MCC-off state), the guard unlock
signal (*LGD) is set to 1 (to enable guard unlocking).
CAUTION
Emergency stop signals (*ESP) via the PMC
<X008#4> (<X000#7> for loader control) and via the
FSSB <DI+000#0> are checked each other
(dual-check for safety input signals), but *ESP via
the PMC <G008#4> is not checked.
Test mode signal
OPT <G191#2>
[Classification] Input signal
[Function] This signal notifies the CNC that MCC off Test mode is set with the
dual check safety function.
Test mode signal (OPT) is not input via the FSSB.
[Operation] When test mode signal (OPT) is 1, the CNC performs safety output
signal MCC off Test processing. (MCC-on enable signals
(MCF1/MCF2) is output in various patterns, and a test is conducted to
see if an appropriate MCC contact state signals (*SMC1/*SMC2)
pattern is input, respectively.) In the emergency stop state or while a
servo or spindle alarm is present, the MCC off test processing is not
performed.
If a MCC off Test is not completed within the time set in parameter
No. 1946, servo alarm No. 488 is issued.