2003/09/05
Edit
EditEdit
Edit
8
9
Data
DataData
Data Si
nature
Si
natureSi
nature
Si
nature
Descri
tion
Descri
tionDescri
tion
Descri
tion
FANUC Series 16i/18i/21i-MB
Parameter check sum function Specifications
-79242EN
Drawing No.
Title
Page
13731 Parameter number 1 to exclude from check sum
::
13750 Parameter number 20 to exclude from check sum
[Data type] Word
[Valid data range ] 0 to +65535
Set parameter number which needs to be excluded from a check sum.
13751 Minimum value 1 of parameter number to exclude from check sum
13752 Maximum value 1 of parameter number to exclude from check sum
::
13769 Minimum value 10 of parameter number to exclude from check sum
13770 Maximum value 10 of parameter number to exclude from check sum
[Data type] Word
[Valid data range ] 0 to +65535
Specify the range of parameter numbers which need to be excluded
from a check sum.
The parameter numbers between minimum value and maximum value
are excluded from a check sum.
NOTE
1. Parameter numbers in minimum value and maximum
value are also excluded from a check sum.
2. If minimum value is bigger than maximum value (min
> max), the setting is invalid.
3. In case that minimum value and maximum value are
same (min = max), the 1 number is excluded.