A-79346E
Title
Draw
No.
Ed. Date Design Description
Date
Jan.06.’04 Design. Apprv.
12/22
page
FANUC Series 30i-MODEL A
Tool management function oversize
tools su
ort
13244 Number of columns of the second cartridge (when the cartridge is of matrix
type)
[Input type] Parameter input
[Data type] Word
[Valid data range] 0 to 1000
When the second cartridge is of matrix type (with bit 1 of parameter No. 13240 set
to 1), set the number of pot columns in this parameter. In this case, ensure that the
condition below is satisfied. The sum of the result of (setting of parameter No.
13243)
×
(setting of parameter No. 13244) and the total number of pots of other
cartridges must not exceed 64 (or a maximum of 1000). If this condition is not
satisfied, or 0 is set in this parameter, the second cartridge is disabled.
13245 Number of rows of the third cartridge (when the cartridge is of matrix type)
[Input type] Parameter input
[Data type] Word
[Valid data range] 0 to 1000
When the third cartridge is of matrix type (with bit 2 of parameter No. 13240 set to
1), set the number of pot rows in this parameter. In this case, ensure that the
condition below is satisfied. The sum of the result of (setting of parameter No.
13245)
×
(setting of parameter No. 13246) and the total number of pots of other
cartridges must not exceed 64 (or a maximum of 1000). If this condition is not
satisfied, or 0 is set in this parameter, the third cartridge is disabled.
13246 Number of columns of the third cartridge (when the cartridge is of matrix
type)
[Input type] Parameter input
[Data type] Word
[Valid data range] 0 to 1000
When the third cartridge is of matrix type (with bit 2 of parameter No. 13240 set to
1), set the number of pot columns in this parameter. In this case, ensure that the
condition below is satisfied. The sum of the result of (setting of parameter No.
13245)
×
(setting of parameter No. 13246) and the total number of pots of other
cartridges must not exceed 64 (or a maximum of 1000). If this condition is not
satisfied, or 0 is set in this parameter, the third cartridge is disabled.