A-79346E
Title
Draw
No.
Ed. Date Design Description
Date
Jan.06.’04 Design. Apprv.
19/22
page
FANUC Series 30i-MODEL A
Tool management function oversize
tools su
ort
1.1 ALARM
Alarm and message
Number Message Description
5312 ILLEGAL COMMAND IN
G10 L75/76/77
In commands from G10 L75/L76/L77
to G11, there is a format error, or a
value beyond the specifiable range is
specified. Correct the program.
5360 TOOL INTERFERENCE
CHECK ERROR
This alarm is issued when interference
with another tool is caused by a data
modification based on G10 data input
or file reading or when an attempt is
made to modify the tool figure data of
a tool registered in the cartridge.
5361 ILLEGAL MAGAZINE
DATA
Tools stored in the cartridge are
interfering with each other.
Reregister the tools in the cartridge, or
modify the tool management data or
tool figure data. If this alarm is
issued, no tool interference check is
made when tools are registered in the
cartridge management table.
Moreover, empty pot search operation
does not operate normally. If this
alarm is issued, the power must be
turned off before operation is
continued.