A-79346E
Title
Draw
No.
Ed. Date Design Description
Date
Jan.06.’04 Design. Apprv.
18/22
page
FANUC Series 30i-MODEL A
Tool management function oversize
tools su
ort
Input to and output from external device
Tool management data and tool figure data can be input to and output from an external device
by using the ALL IO screen or the tool management screen.
For output to an external device, data is output in the G10 format.
For input/output of tool figure numbers and tool figure data of the tool management data, the
option for supporting oversize tools with the tool management function is required.
When data is output to an external device without specifying a file name, the following
default file names are used:
“TOOL_MNG.TXT” Tool management data
“TOOLGEOM.TXT” Tool geometry data
NOTE
・If a target tool is registered in a cartridge and interferes with other tools in
registration or modification of tool figure data of the tool management
data, PS alarm 5360 is issued. (The data is not input.)
・If a tool interferes with other tools in registration in or modification to the
cartridge management table, PS alarm 5360 is issued. (The data is
not input.)
・If an attempt is made to modify tool figure data, and the tool for which the
tool figure data number subject to modification is set is registered in the
cartridge, PS alarm 5360 is issued. (The data is not input.)
・When restoring backup data in the state where all data related to the tool
management function in the NC is cleared, restore tool figure data, tool
management data, and cartridge management table data in this order.