A-78622E
Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
4/12
Date
Design
Descri
tion
Date
FANUC Series 16i /18i /21i -MB/TB
Machine Alarm Diagnosis
Specifications
2001.10.19
M.Kobayashi HKochiya
02 2001.11.07
dd
arameter, etc
2.1.Making a guidance table (1)
Alarm No., Classified code, Alarm message, Probable cause and etc. are registered into a
guidance table (1).
Input items
(a) Alarm No.
Input alarm numbers of the external alarm message or the macro alarm.
Max 5 figures (Range: 0-65535).
Ex.) In case of the external alarm message alarm No.1000
"1000"
(b) Classified code
Two codes (Code 1 and Code 2) are available.
These codes are displayed at 1st line on the trouble diagnosis guidance screen as
"[Code 1] - [Code 2]".
- Code 1
Input the type of the alarm and so on.
Max 2 characters.
Caution
A character string "NC" is reserved as the code 1 of CNC alarm. Do not
use "NC" as the code 1.
- Code 2
Input the alarm No. and so on.
Max 16 characters.
(c) Alarm message
Max 32 characters ∗ 1 line.
It is displayed at 2nd line on the trouble diagnosis guidance screen.
(b)(a) (c) (d) (e) (f)