A-78622E
Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
7/12
Date
Design
Descri
tion
Date
FANUC Series 16i /18i /21i -MB/TB
Machine Alarm Diagnosis
Specifications
2001.10.19
M.Kobayashi HKochiya
02 2001.11.07
dd
arameter, etc
2.2.Making a guidance table (2)
"Guidance message" is registered into a guidance table (2). "Guidance message" is a
question and an instruction to an operator.
Input items
(a) Message ID
A Message ID specifies a guidance message.
Max 6 characters with capital letters.
Ex.) In case of the first message for the external alarm message alarm No.1000
"1000A"
Ex.) In case of the second message for the external alarm message alarm No.1000
"1000B"
Caution
Message IDs starting with "M" are reserved for a jump to MTB's guidance
table from a CNC guidance table.
Ex.) "M205", "M407"
Do not use a message ID starting with "M" for the other purpose.
Please refer to "2.4 Jump from CNC guidance table to MTB's guidance
table".
(b) Guidance message
Write a question, an instruction and so on to operators.
Max 32 characters ∗ Max 4 lines.
It is displayed at the part of "GUIDANCE" on the trouble diagnosis guidance screen.
- If 32 characters are displayed in one line, the next character is automatically
displayed in a new line.
- If a new line is required on purpose, write "\n". "\n" is not counted in the number of
characters.
- The total number of lines must be within 4 lines.
(b)(a) (c) (d)