A-78622E
Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
8/12
Date
Design
Descri
tion
Date
FANUC Series 16i /18i /21i -MB/TB
Machine Alarm Diagnosis
Specifications
2001.10.19
M.Kobayashi HKochiya
02 2001.11.07
dd
arameter, etc
(c) Next message ID
Next message ID specifies a guidance message which is displayed after an operator
pushes a soft-key [YES]/[NO] to answer a question.
Max 6 characters with capital letters.
- Input "-1" when there is no next message ID to display after a soft-key [YES]/[NO] is
pushed.
- Input "-1" for both YES and NO in case of the end of a diagnosis.
(d) Notes
It is possible to write some notes here.
Operation of buttons
- [Check] button
When [Check] button is pushed, a range of number, a number of characters and
invalid character codes are checked.
If the result is OK, a string of the cell under the button is changed from "Unchecked" to
"OK". If the result is NG, the string is changed to "NG". And the cell color becomes
green. And a comment, which can display the cause of error, is added to the cell.
Ex.)
And when a message ID starting with "M" is found the cell color becomes sky blue.
Ex.)